Apex Dual Orin DIP Switch#
#
Function#
DIP |
No. |
Description |
Comment |
---|---|---|---|
SW3 |
1 |
TC397 CAN0 Terminal Resistance Selection |
ON with 120Ω Terminal Resistance (Default) OFF no Terminal Resistance |
SW3 |
2 |
TC397 CAN1 Terminal Resistance Selection |
ON with 120Ω Terminal Resistance (Default) OFF no Terminal Resistance |
SW3 |
3 |
主ORIN CAN0 Terminal Resistance Selection |
ON with 120Ω Terminal Resistance (Default) OFF no Terminal Resistance |
SW3 |
4 |
主ORIN CAN1 Terminal Resistance Selection |
ON with 120Ω Terminal Resistance (Default) OFF no Terminal Resistance |
SW3 |
5 |
从ORIN CAN0 Terminal Resistance Selection |
ON with 120Ω Terminal Resistance (Default) OFF no Terminal Resistance |
SW3 |
6 |
从ORIN CAN1 Terminal Resistance Selection |
ON with 120Ω Terminal Resistance (Default) OFF no Terminal Resistance |
SW3 |
7 |
TC397 CAN2 Terminal Resistance Selection |
ON with 120Ω Terminal Resistance (Default) OFF no Terminal Resistance |
SW3 |
8 |
TC397 CAN3 Terminal Resistance Selection |
ON with 120Ω Terminal Resistance (Default) OFF no Terminal Resistance |
SW4 |
1 |
Power mode switch 1 |
See detail below. |
SW4 |
2 |
Power mode switch 2 |
See detail below. |
Auto Mode(Default)#
Device boot once power is on.
IGN&CAN Wakeup Mode#
Device will not boot when power on, controlled by IGN and CAN wakeup.